Power required: 115/230 Vac, 50 or 60 Hz, 60W
Output: 12 or 24 Vdc, 4A continuous
Holding Current: Can be limited to 3000mA, switch selectable
In-rush capacity: Up to 16 A
Relay contacts: 10A, SPDY, Form C
Lock control: Fail safe, fail secure or both on same door
Battery back-up: 12Vdc or 24Vdc, automatic transfer and charging, batteries optional
Audit Trail: No-volatile memory records last 1,000 events, including all access attempts and alarms
Audit Trail data Port: RS-232
Battery monitoring: Warning lamp and alarm activate when battery is low
Door Open duration: 3 to 60 seconds
Penalty function: Invalid attempts temporarily disable operation and sound alarm
Door monitoring functions: Anti-follow through and door propped and forced door alarms
Door contact input: Dry contact closure
Remote release: External dry contact closure
Keypad: 15 ft. lengh, 10-conductor, #22, max. length 200 ft.
Enclosure: 19 gauge steel, powder coated, gray color, knockouts for conduit, cam-lock and holes for padlock
Dimensions: 12H x 9W x 4.5D in.